@RTT
Loading device data
Setting
Command
@RTT, ch (, table)
Response
@RTT, ch (, table)
Parameter
ch: Input channel
1 = IN1 to 8 = IN8
table: Device table
1 to 99 (Registered device data),
100 to 100+n (Preset device data. ”n” varies depending on input signal,
but 0 for most cases.)
Only for analog input, specify the device table.
Setting
example
Command
Response
@RTT,1
@RTT,1
Description Reconfiguring IN1 input timing setting to the value detected automatically.
Setting
example
Command
Response
@RTT,6,2
@RTT,6,2
Description Setting IN6 input timings to the values saved in the device table 2.
Remarks
This command is valid only if signal is input.
For analog input, this command is valid only if the device data of input signal is
registered.
@STT
Registering device data
Setting
Command
@STT, ch, table (, name)
Response
@STT, ch, table (, name)
Parameter
ch: Input channel
6 = IN6, 7 = IN7
table: Device table
1 to 99
name: Device table name
Up to 14 characters from 20 to 7D of ASCII code.
You can skip “Device table name”. If you skip it, only input timing setting is saved.
However, if no device table name is currently saved, the resolution is saved
automatically as the device table name.
Setting
example
Command
Response
@STT,7,2
@STT,7,2
Description Saving IN7 input timing setting in device table 2 without editing the device table
name.
Setting
example
Command
Response
@STT,7,2,XGA 60Hz
@STT,7,2,XGA 60Hz
Description Saving the current IN7 input timing setting in device table 2 with the name of
“XGA 60Hz”.
Remarks