MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
79
@GLF / @SLF
LAN communication mode
Getting
Command
@GLF, connection
Response
@GLF, connection, mode (, ip_1, ip_2, ip_3, ip_4, pjlink, tcp, password)
Setting
Command
@SLF, connection, mode (, ip_1, ip_2, ip_3, ip_4, pjlink, tcp, password)
Response
@SLF, connection, mode (, ip_1, ip_2, ip_3, ip_4, pjlink, tcp, password)
Parameter
connection: Connection number
1 = connection 1 to 8 = connection8
mode: Operation mode
0 = RECEIVER mode [Default], 1 = TRANSMITTER mode
ip_1: Upper bit of the destination IP address to ip_4: lower bit of the destination IP
address
0 to 255 = 8 bit (Decimal notation) [Default] 192.168.1.198
Available only if the
mode
is TRANSMITTER.
pjlink: PJLink protocol connection
0 = PJLink not used [Default], 1 = PJLink used
Available only if the
mode
is TRANSMITTER.
tcp: Destination port number
1 to 65535 [Default] 1100
Available only if the
mode
is TRANSMITTER and “pjlink” is set to “0” (PJLink not
used).
If “pjlink” is set to “1” (PJLink used), “tcp” is “4352” fixed.
password: Password of PJLink protocol
Up to 32 characters of the following ASCII codes: 20, 30 to 39, 41 to 5A, 61 to
7A (alphanumeric characters). [Default] All: 20 (space)
Replied/Set only if the
mode
is “1” (TRANSMITTER) and
pjlink
is “0” (PJLink
not used).
Getting commands: replied only if the password is set.
Setting commands: you can skip this password setting if you disable password
authentication for PJLink protocol connection.
Available only if the
mode
is TRANSMITTER and “pjlink” is set to “0” (PJLink not
used).
Getting commands: returned only if the password is set.
Setting commands: you can skip this password setting if you do not use password
authentication for PJLink protocol connection.
Getting
example
Command
Response
@GLF,3
@GLF,3,1,192,168,1,2,1,PROJECTOR1
Description Getting mode settings of connection 3.
Mode = TRANSMITTER mode, destination IP address = 192.168.1.2,
PJLink = to be used, password = “PROJECTOR1”
Setting
example
Command
Response
@SLF,3,1,192,168,1,2,1
@SLF,3,1,192,168,1,2,1
Description Setting connection 3 as follows:
Mode = TRANSMITTER mode, destination IP address = 192.168.1.2,
PJLink = to be used, password = disabling password authentication.
Remarks
If IP address or RS-232C communication setting is changed, the communication