MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
94
@GTF / @STF
Blinking time of sink device power switch
Getting
Command
@GTF, control _1 (,control _2
・・・
)
Response
@GTF, control _1, flash_1 (,control _2, flash_2
・・・
)
Setting
Command
@STF, control _1, flash_1 (,control _2, flash_2
・・・
)
Response
@STF, control _1, flash_1 (,control _2, flash_2
・・・
)
Parameter
control _1-3: Command keys that are connected to command control connectors
0 = All command keys that are connected to command control connectors,
1 = COMMAND A to 3 = COMMAND C
10 = DISPLAY1 POWER, 11 = DISPLAY2 POWER
flash_1-13 : Blinking time
-1 = Links during control command execution,
0 = Not blink,
1 to 1000 = Blinks for 1 sec. to 1000 sec.
[Default] COMMAND A to COMMAND 3 = 0,
DISPLAY1 POWER, DISPLAY2 POWER = -1
Getting
example
Command
Response
@GTF,1
@GTF,1,-1
Description Getting blinking time of COMMAND A.
The switch will be blinked while control command is being executed.
Setting
example
Command
Response
@STF,1,5
@STF,1,5
Description Setting COMMAND A to blink 5 seconds after control command execution starts.