Introduction
This chapter describes the SmartAXIS maintenance communication function.
Maintenance communication is a communication protocol dedicated for IDEC programmable controllers. It is used when WindLDR
or an IDEC operator interface communicates with the SmartAXIS.
Maintenance communication of SmartAXIS is available on USB port (WindLDR only), expansion communication ports, and Ethernet
port, allowing the optimum communication method to be selected for a variety of system configurations.
Maintenance Communication Functions
When performing maintenance communication with the SmartAXIS, the following functions can be used:
Note:
To use maintenance communication, see "Start WindLDR" on page 4-1 and perform setup.
Communication Ports Used For Maintenance Communication
SmartAXIS supports the following communication ports:
Note:
Communication cartridges are required in order to use expansion communication ports.
Maintenance communication supports the following functions on each communication port:
Function
Description
Download user programs
User programs created in WindLDR can be downloaded to the SmartAXIS.
See "Download Program" on page 4-16.
Upload user programs
User programs stored in the SmartAXIS can be uploaded to WindLDR.
Monitor/change device values
The user program and the device values of the SmartAXIS can be monitored and the device values can be
changed using WindLDR.
See "Monitor Operation" on page 4-17.
Download system software
System software can be downloaded to the SmartAXIS.
See "Upgrade SmartAXIS System Software" on page A-2
.
Type
USB Port
(Port 1)
Expansion Communication Ports (Note)
Ethernet Port
Port 2
Port 3
12-I/O type
Yes
No
No
No
24-I/O type
Yes
Yes
No
Yes
40-I/O type
Yes
Yes
Yes
Yes
48-I/O type
Yes
Yes
Yes
Yes
Communication
Port
Standard/Option
No. of Ports
Communication Settings
USB port
Standard
1
None
Expansion
communication
ports
Options
FT1A-PC1: EIA RS232C (Mini DIN)
FT1A-PC2: EIA RS485 (Mini DIN)
FT1A-PC3: EIA RS485
(Terminal block)
12-I/O type: 0
24-I/O type: 1
40-I/O type: 2
48-I/O type: 2
Function area settings
See "Maintenance Communication via
Expansion Communication Port" on
page 9-3.
Ethernet Port
12-I/O type: -
24-I/O type: Standard
40-I/O type: Standard
48-I/O type: Standard
1
Function area settings
See "Maintenance Communication via
Ethernet Port" on page 9-5.
Communication
Port
Maintenance Communication Functions
Monitor/Change Device Values
Download/Upload
User Programs
Download System Software
USB port
Yes
Yes
Yes
Expansion
communication
ports
Yes
No
No
Ethernet port
Yes
Yes
No
Summary of Contents for SmartAXIS FT9Z-1A01
Page 1: ...FT9Y B1378 7...
Page 10: ...TABLE OF CONTENTS Preface 9 SMARTAXIS PRO LITE USER S MANUAL FT9Y B1378...
Page 212: ...7 DEVICE ADDRESSES 7 16 SMARTAXIS PRO LITE USER S MANUAL FT9Y B1378...
Page 230: ...8 INSTRUCTIONS FUNCTION BLOCKS REFERENCE 8 18 SMARTAXIS PRO LITE USER S MANUAL FT9Y B1378...
Page 344: ...13 SCRIPTS 13 36 SMARTAXIS PRO LITE USER S MANUAL FT9Y B1378...
Page 386: ...APPENDIX Appendix 16 SMARTAXIS PRO LITE USER S MANUAL FT9Y B1378 Japanese Font JIS X0201...
Page 393: ......