38
Response 80 / 100 / 120
- Installation
60
BURNER REPLACEMENT
1. Remove front and sealing panels. Refer to Frame 48.
2. Remove the fan assembly. Refer to Frame 49.
3. Disconnect the 2 ignition leads and one detection lead
from the electrodes.
4. Undo the 3 fixing screws securing the burner assembly.
5. Withdraw the burner assembly downward and out of the
heat exchanger, taking care not to damage the electrodes.
6. Remove the spark and detection electrodes. Refer to
Frame 58.
7. Remove the 3 securing screws and withdraw the burner
from the mounting flange.
8. Fit the new burner, replacing any damaged or
deteriorating gasket.
9. Re-assemble in reverse order.
Note.
Check the spark and detection gaps.
61
BURNER INJECTOR REPLACEMENT
SERVICING
SER
VICING
1. Refer to Frame 48.
2. Unscrew the injector from the
gas injection pipe.
3. Check that the new injector is
of the correct size then screw
in place.
4. Re-assemble in reverse order.
Summary of Contents for responce 100
Page 1: ......
Page 62: ...62 Response 80 100 120 Installation NOTES ...