25 CUTTING THE FLUE TO LENGTH
1. The flue cut length is calculated as detailed
in Frame 10.
2. Measure from the groove and mark the tube.
3. To ensure the tube is cut square, mark the
flue all the way round, using, e.g. a long
straight strip of paper with its ends
overlapped.
4. Cut to length, using the cardboard support
aid.
5. Remove the cardboard support and any
burrs.
26
FITTING THE FLUE
For flue lengths greater than 600mm refer to Frames 30 to 32 - Flue Extension
Ducts
or
b.
Use stand-off channels
(To allow pipework to be taken upwards).
!
!
!
!
!
Insert the wall plugs.
!
!
!
!
!
Put the screws into the wall plugs and leave 10mm
proud.
!
!
!
!
!
Fasten each channel to the frame with the 6mm
screws provided.
!
!
!
!
!
Hang channels and frame onto the screws and
tighten up.
Note.
If the clearances above and below the boiler are less
than the length of the pipes it will be necessary to position
the pipes behind the wall mounting plate BEFORE the
plate is screwed to the wall.
Flues up to 600mm (23
5/8
")
1. Attach the clamping/sealing rings to the flue (this
prevents the assembly being pushed right through the
hole and causing an accident).
2. Pass the cut flue through the prepared hole, ensuring
that the groove is uppermost.
3. Pull the flue back to compress the rubber seal and fix
in place with the clamping/sealing rings.
Note.
To facilitate turret fixing or removal do NOT make good the
wall.
INSTALLATION
SIDE FLUE OUTLET
Make service water, gas & electrical connections. Go to Frames 35, 36 & 39 then return to Frame