13
Minimiser
-
Installation
FLUE KITS
Pack B
- supplied as standard
Pack D
- optional extension kit for side flue
or rear flue outlet.
Refer to 'Flue Extension Ducts'
13 BOTTOM PANEL REMOVAL
INST
ALLA
TION
IMPORTANT.
The boiler MUST be installed in a vertical position
INSTALLATION
Bottom
panel
Dimension X - Wall thickness
Dimension Y - Wall thickness plus
boiler spacing (RHS)
Dimension Z - Wall thickness plus
boiler spacing (LHS)
Notes.
1.
The flue duct MUST be inclined at 2.5
0
to the horizontal
to allow condensate to drain back into the boiler and out
through the condensate drain.
2.
If the front of the boiler is to be flush with the front of
300mm deep kitchen units then the optional stand-off
bracket kit should be used. Care must be taken when
cutting the ducts and marking the wall to suit this condition.
Flue length dimension
Flue
Rear flue
Right hand side
Left hand side
packs
dimn. X
flue dimn. Y
flue dimn. Z
required
114 - 732 mm
114 - 614 mm
114 - 698 mm
Pack B, cut down
(4
1/2
- 28
3/4
")
(4
1/2
- 24
1/8
" )
(4
1/2
- 27
1/2
" )
as in Frames 18 & 26
732 - 1931 mm
614 - 1813 mm
698 - 1897 mm
Pack B (1 off) and
(28
3/4
- 76")
(24
1/8
- 71
3/8
")
(27
1/2
- 74
3/4
")
Pack D (1 off)
1931 - 3130 mm
1813 - 3012 mm
1897 - 3096 mm
Pack B (1 off) and
(76 - 123
1/4
")
(71
3/8
- 118
5/8
") (74
3/4
- 121
7/8
")
Pack D (2 off )
1.
Undo the three retaining screws.
2.
Push the panel backward then to the right to withdraw it
from the boiler.
3.
Unpack the boiler flue kit (and extension packs, if used).
14 DETERMINING THE FLUE LENGTH AND FLUE PACKS REQUIRED