ClearMark™
Installation, Operation & User Manual
–
Page 108
V 1.S.10 January 2021
V-1.S.1
Junction box Components
The Junction Box includes the following components:
-
AC input plug with filter.
-
Internal power supply to provide the required 24Vdc to the print heads.
-
Electronic distribution board with connections.
-
4 LEDs to indicate the state of the printers connected.
AC Filter
Utilizes 2 fuses - 5 x 20 mm, 3.15 A.
NOTE
: Verify that both 3.15 A fuses are connected and they are in good working order if the
Junction Box does not power up.
24Vdc Power supply
Junction Box contains a 24Vdc power supply to supply up to 4 TIJ printers:
-
Mean well LRS-100-24.
-
AC Input: 88
–
264Vac.
-
AC current (Typ.): 1.9A / 115Vac
–
1.2 A / 230Vac.
-
Frequency range: 47
–
63 Hz.
-
Operating temperature from -30°C to 70°C.
-
No load power consumption < 0.3W.
-
Max power consumption: 108 W.
-
Max output current: 4.5 A.
Electronic board
The electronic board distributes the common signals for up to 4 connected printers and powers
the HMI. The heads can be powered by external power bricks or by the junction box itself (See
Jumpers section for details).