© 2007 ICS, Blount Inc.
F/N 518537 Oct 07
TITLE
603GC SERVICE MANUAL
28
8. STARTER
8.6
Remove starter pulley.
A Remove pulley screw.
8.7
Inspect coil spring.
A Replace if spring hook is damaged.
Attempting to re-bend the spring
hook may cause the hook to
break off.
B Carefully remove coil spring
and housing to prevent spring
from unwinding.
8.8
Lubricate with light weight oil.
8.9
Replace parts carefully.