F/N 518537 Oct 07
© 2007 ICS, Blount Inc.
TITLE
603GC SERVICE MANUAL
79
25.6 If the pressure does not reduce
to 0 psi, disassemble or replace
the breather.
A Disassemble by snapping off cap.
B Clean parts with solvent or fuel.
25.7 Assemble in reverse order.
A Make sure duck bill opens easily.
B Make sure that the spring taper is
oriented in the correct direction.
C Assemble by snapping cap in place.
25. FUEL SYSTEM LEAKS