F/N 518537 Oct 07
© 2007 ICS, Blount Inc.
TITLE
603GC SERVICE MANUAL
27
8. STARTER
8
This section covers the
removal of the starter cover,
replacement of the starter rope,
and replacement of the
recoil spring.
8.1
Remove starter cover screws.
8.2
Remove starter cover assembly
from saw.
8.3
Remove starter cord shield screws.
8.4
Relieve spring tension.
A Pull 4-6” (10-15 cm) of rope out.
B Line rope up with notch on pulley.
C To release pulley, slowly rotate
pulley counterclockwise until spring
pressure is released. Use thumb
as a brake.
8.5
Remove rubber screw seal.