IR-712A Universal IR Learning Remote Module (Ver. 1.3, Aug/23/2016) 20
Figure 3-4
The basic settings window for IR-712A.
These settings include:
[1]
COM Port : The COM port of
IR-712A.
(RS-232/RS-485, default: RS-232)
(*)
[2]
Baud Rate
:
The baud rate of the COM port
(9600~115200 bps
,
default: 115200)
[3]
Parity
:
Parity bit (NONE / ODD / EVEN
,
default
:
NONE)
[4]
Data Bits
:
Data bit (This value is fixed in 8)
[5]
Stop Bits
:
Stop bit (1 / 2, default:1)
[6]
Net ID
:
Modbus Network ID
(1~247, default: 1)
[7]
GapTime
:
The max space time in an IR protocol (Fig. 3-5). For example,
GapTime should be set to the value greater than 40 ms to learn IR
commands successfully for the Sharp remote control.
(6 ~ 200 ms, default
:
72 ms)
Figure 3-5
A complete IR Command with a large Gap Time.
[8]
MB Cmd Resp Delay Time:
The delay time before the IR-712A responses each
request from the Modbus master devices (Modbus command
response delay time: 0 ~ 60 ms; default: 3 ms)
* Note
: Please refer to the section 2-4.
The
“Get Setting” button will be executed once when the “Basic Settings” window is
opened in the beginning. Three buttons located at the right side of the window are
described in the Table 3-2.
Table 3-2: Three buttons in the window of basic settings