IR-712A Universal IR Learning Remote Module (Ver. 1.3, Aug/23/2016) 12
2.5 Watchdog Timer
Watchdog timer is a kind of timer to reset IR-712A while there is some error occurred
in the system and the recovery is not possible within a short time (several
milliseconds).
Users can open the case of IR-712A and adjust the JP1 to enable or disable the
watchdog timer as depicted in Figure 2-11. The default setting to the watchdog timer is
“Enable”.
Enable (default) Disable
Figure 2-11
JP1 for the watchdog timer of IR-712A.