CAN-2084C
User’s Manual (Version 1.00, Sep/2018) ------------- 24
8h
Channel 7 Frequency mode
UNSIGNED 32
RW
0
Note: When user set 2004 to 02(Frequency mode), user can use 3004
to determine which mode you want
Frequency Mode
Type Code
Frequency Mode
0 (default)
Normal mode
1
High speed mode
Frequency Time Out Value Entry
Idx
Sidx
Description
Type
Attr Default
3005h
0h
Number of entries
UNSIGNED 8
RO
8h
1h
Channel 0 frequency time out value
UNSIGNED 16 RW 0BB8h
…
…
…
…
…
8h
Channel 7 frequency time out value
UNSIGNED 16 RW 0BB8h
Note:
Frequency time out value:
Default: 0xBB8 (3000ms)
Range: 0x0 ~ 0xFFFF
For example:
To measure 1k Hz frequency.
In normal mode, only needs 1 ms to update frequency value.
In High Speed mode, it will measure 11 times (necessary 1ms*11=11ms) and
calculate frequency value.
Low Pass Filter Entry
Idx
Sidx
Description
Type
Attr
Default
3006h
0h
Number of entries
UNSIGNED 8
RO
8h
1h
Channel 0 Low pass filter
UNSIGNED 8
RW
0
…
…
…
…
…
8h
Channel 7 Low pass filter
UNSIGNED 8
RW
0
Note: 0 = Disable , 1 = Enable
Low Pass Filter Period Entry
Idx
Sidx
Description
Type
Attr
Default
3007h
0h
Number of entries
UNSIGNED 8
RO
8h
1h
Channel 0 Low pass filter period UNSIGNED 16
RW
1
…
…
…
…
…
8h
Channel 7 Low pass filter period UNSIGNED 16
RW
1
Note: Time
Range: 1μs ~ 32767μs
Summary of Contents for CAN-2084C
Page 4: ...CAN 2084C User s Manual Version 1 00 Sep 2018 4 Figure 1 1 CAN 2084C...
Page 8: ...CAN 2084C User s Manual Version 1 00 Sep 2018 8 2 Hardware 2 1 Structure Top View Bottom View...
Page 11: ...CAN 2084C User s Manual Version 1 00 Sep 2018 11 2 4 PIN Assignment...
Page 35: ...CAN 2084C User s Manual Version 1 00 Sep 2018 35...
Page 36: ...CAN 2084C User s Manual Version 1 00 Sep 2018 36...