2001 NEW
21
2001 NEW
7
CALL PROCEDURE
7
■
Distress call to ships
General DSC calls with the “distress” category may be
sent after the Distress call. For example, you want to
change the operating frequency, and so on.
The call is transmitted one time only although the dis-
tress call using the [DISTRESS] switch is repeated 5
times.
R X
J 3 E
GPS
1 2 . 3 4 5 . 0
E x i t
S P
L a t 3 4 3 4 ' N
L o n 1 3 5 3 4 ' E
1 2 : 3 4
* * * * * * * D S C M E N U * * * * * * *
- - - - - - - - S e l e c t - - - - - - - -
P o s i t i o n
I n d i v i d u a l
G r o u p
G e o g r a p h i c a l
P o s i t i o n R E Q
D i s t r e s s
T e s t
R X m e m o r y
T X m e m o r y
S e t u p
E x i t
Ç
O K
S E L
* * * * * * I n d i v i d u a l * * * * * *
- - - - - - - C a t e g o r y - - - - - - -
R o u t i n e
S a f e t y
U r g e n c y
D i s t r e s s
Ç
O K
S E L
* * * * * * I n d i v i d u a l * * * * * *
- - - - - - A d d r e s s I D - - - - - -
M a n u a l s e t
I C - M 8 0 2 - 1 1 2 3 4 5 6 7 8 9
I C - M 8 0 2 - 2 1 2 3 4 5 6 7 8 8
I C - M 8 0 2 - 3 1 2 3 4 5 6 7 8 7
I C - M 8 0 2 - 4 1 2 3 4 5 6 7 8 6
I C - M 8 0 2 - 5 1 2 3 4 5 6 7 8 5
Ç
O K
S E L
* * * * * * I n d i v i d u a l * * * * * *
- - - - - - A d d r e s s I D - - - - - -
9 8 7 6 5 4 3 2 1
O K
* * * * * * I n d i v i d u a l * * * * * *
- - T r a f f i c f r e q u e n c y - - -
M a n u a l s e t
T : 4 5 6 7 . 0 k H z I C - M 8 0 2 - 1
R : 4 5 6 7 . 0 k H z
T : 1 2 3 4 5 . 0 k H z I C - M 8 0 2 - 2
R : 1 2 3 4 5 . 0 k H z
Ç
O K
S E L
* * * * * * I n d i v i d u a l * * * * * *
- - T r a f f i c f r e q u e n c y - - -
T X : _ 2 1 3 4 . 0 k H z
R X : _ 2 1 3 4 . 0 k H z
O K
S E L
* * * * * * I n d i v i d u a l * * * * * *
- - - - C a l l f r e q u e n c y - - - -
2 1 8 7 . 5 k H z
4 2 0 7 . 5 k H z
6 3 1 2 . 0 k H z
8 4 1 4 . 5 k H z
1 2 5 7 7 . 0 k H z
1 6 8 0 4 . 5 k H z
Ç
O K
S E L
* * * * * * I n d i v i d u a l * * * * * *
- - - - - - - - - C a l l - - - - - - - - -
C a t e g o r y : D i s t r e s s
T o : 9 8 7 6 5 4 3 2 1
T r a f f i c : R a d i o t e l e p h o n e
T X 2 1 3 4 . 0 k H z
R X 2 1 3 4 . 0 k H z
C a l l f r e q : T X 2 1 8 7 . 5 k H z
R X 2 1 8 7 . 5 k H z
W r i t e - M e n u
C a l l
DSC menu
Category selection
Traffic frequency selection 1
Traffic frequency selection 2
Call frequency selection
Call stand-by screen
Manual ID input
Address ID selection
Hold down [CANCEL/CALL] for 1
second to start calling.
Hold down [ENT] for 1 second to
store the information into a TX
memory channel.
D
Operation Outline
Summary of Contents for IC-M802
Page 1: ...MF HF MARINE TRANSCEIVER iM802 INSTRUCTION MANUAL ...