3
V4.01–
A-7264-2EX
Command table (Continued)
Cmd.
Sub
cmd.
Set mode
Data
Description
Category Item
1A
05
03
18
00/01 Send/read the Built-in Test Display
(00=OFF, 01=ON)
19
00/01 Send/read the Opening Display
(00=OFF, 01=ON)
04
00
01 to
30
Send/read the Link Interval setting
( 01 to 30=10 to 300 second(s) in 10
second steps)
06
00
00 to
06
Send/read the I Key setting
( 00=Not assigned, 01=Menu,
02=Manager, 03=Setmode,
04=Address list, 05=Call In list,
06=Call Out list)
01
00 to
06
Send/read the II Key setting
( 00=Not assigned, 01=Menu,
02=Manager, 03=Setmode,
04=Address list, 05=Call In list,
06=Call Out list)
02
00 to
06
Send/read the III Key setting
( 00=Not assigned, 01=Menu,
02=Manager, 03=Setmode,
04=Address list, 05=Call In list,
06=Call Out list)
07
00
00 to
02
Send/read the LSB mode capability
( 00=Disable, 01=RX, 02=RX & TX)
01
00
Send/read the Offset frequency for
the LSB mode
(00=1500 Hz)
02
01 to
30
Send/read the IF filter passband
width for the LSB mode
( 01 to 30=100 to 3000 Hz in 100 Hz
steps)
03
01 to
03
Send/read the connector for the
LSB mode data modulation when an
external unit’s PTT is pushed
( 01=USB, 02=ACC, 03=TC4)
08
00
00 to
02
Send/read the USB mode capability
( 00=Disable, 01=RX, 02=RX & TX)
01
00
Send/read the Offset frequency for
the USB mode
(00=1500 Hz)
02
01 to
30
Send/read the IF filter passband
width for the USB mode
( 01 to 30=100 to 3000 Hz in 100 Hz
steps)
03
01 to
03
Send/read the connector for the
USB mode data modulation when
an external unit’s PTT is pushed
( 01=USB, 02=ACC, 03=TC4)
09
00
00 to
02
Send/read the CW mode capability
( 00=Disable, 01=RX, 02=RX & TX)
01
00
Send/read the Offset frequency for
the CW mode
(00=800 Hz)
02
01 to
30
Send/read the IF filter passband
width for the CW mode
( 01 to 30=100 to 3000 Hz in 100 Hz
steps)
10
00
00 to
02
Send/read the AM mode capability
( 00=Disable, 01=RX, 02=RX & TX)
01
00
Send/read the Offset frequency for
the AM mode
(00=0 Hz)
Cmd.
Sub
cmd.
Set mode
Data
Description
Category Item
1A
05
10
02
01 to
50
Send/read the IF filter passband
width for the AM mode
( 01 to 50=200 to 10000 Hz in 200
Hz steps)
03
01 to
03
Send/read the connector for the
AM mode data modulation when an
external unit’s PTT is pushed
( 01=USB, 02=ACC, 03=TC4)
11
00
00 to
02
Send/read the RTTY mode
capability
( 00=Disable, 01=RX, 02=RX & TX)
01
00 to
06
Send/read the RTTY mark
frequency
( 00=1200 Hz, 01=1275 Hz,
02=1487.5 Hz, 03=1615 Hz,
04=1700 Hz, 05=2100 Hz,
06=2125 Hz)
02
00 to
03
Send/read the RTTY shift frequency
( 00=170 Hz, 01=200 Hz,
02=425 Hz, 03=850 Hz)
03
00/01 Send/read the keying polarity.
( 00=NORMAL, 01=REVERSE)
12
00
00 to
02
Send/read the LSBD1 mode
capability
( 00=Disable, 01=RX, 02=RX & TX)
01
00 to
02
Send/read the Offset frequency for
the LSBD1 mode
( 00=1500 Hz, 01=1650 Hz,
02=1800 Hz)
02
01 to
30
Send/read the IF filter passband
width for the LSBD1 mode
( 01 to 30=100 to 3000 Hz in 100 Hz
steps)
03
01 to
03
Send/read the connector for the
LSBD1 mode data modulation when
an external unit’s PTT is pushed
( 01=USB, 02=ACC, 03=TC4)
13
00
00 to
02
Send/read the USBD1 mode
capability
( 00=Disable, 01=RX, 02=RX & TX)
01
00 to
02
Send/read the Offset frequency for
the USBD1 mode
( 00=1500 Hz, 01=1650 Hz,
02=1800 Hz)
02
01 to
30
Send/read the IF filter passband
width for the USBD1 mode
( 01 to 30=100 to 3000 Hz in 100 Hz
steps)
03
01 to
03
Send/read the connector for the
USBD1 mode data modulation
when an external unit’s PTT is
pushed
( 01=USB, 02=ACC, 03=TC4)
14
00
00 to
02
Send/read the LSBD2 mode
capability
( 00=Disable, 01=RX, 02=RX & TX)
01
00 to
02
Send/read the Offset frequency for
the LSBD2 mode
( 00=1500 Hz, 01=1650 Hz,
02=1800 Hz)
02
01 to
30
Send/read the IF filter passband
width for the LSBD2 mode
( 01 to 30=100 to 3000 Hz in 100 Hz
steps)