MAINTENANCE
Cleaning
DO NOT
use harsh solvents such as
benzine or alcohol when cleaning,
because they will damage the transceiver
surfaces.
If the transceiver becomes dusty or dirty,
wipe it clean with a dry, soft cloth.
Replacing fuse
If a fuse blows, or the transceiver stops functioning,
find and repair the cause of the problem. Then replace
the damaged fuse with a new, adequately rated fuse.
L
Spare fuses are supplied with the transceiver.
The fuses are installed in the DC power cable and in
the inside circuitry, to protect the transceiver.
•DC power cable fuses ................................. ATQ 25 A
•Circuitry fuse ................................................. ATC 5 A
1
2
3
ATQ 25 A fuse
1.
Remove the 18 screws, then remove the cover.
2.
Remove the 13 shield screws, then remove the
shield cover.
Shield cover
Cover
3.
Replace the circuitry fuse as shown below.
CAUTION:
When you remove a fuse, use longnose
pliers to protect your fingers and the fuse holders.
ATC 5 A fuse
4.
Replace the removed parts.
R
WARNING!
• Disconnect the DC power cable from the transceiver
before replacing the fuse.
•
NEVER
use fuses that are not specified.