13
Install it independently in an earth leakage circuit breaker with more than 20A
and provide an external grounding.
(Ask a qualified electrical technician for the installation.)
The power cable should be connected before the product can be operated normally.
The air suction and discharge should be facilitated so that the cooling performance can be optimized.
For better taste of soft ice cream, do not miss the filter cleaning time.
It is recommended to clean the cylinder, the mix tank, the impeller, the dasher,
the carburetor, the piston every day.
Clean the condenser at least once a month or more often.
The cylinder, impeller, dasher, or piston inside the product makes a contact
with the ingredient, so you should clean them once every day.
If you intend to leave it unused for a long time, wash it and turn off the water supply
valve and turn off the earth leakage circuit breaker.
●
Do not block the air vent.
Floor suction
Upper discharge
●
Periodic filter cleaning(Once a week). - Air cooled type
●
Clean the condenser once a month. - Air cooled type
●
Pasteurize it at least once a day.
For your
information
This product is for 230V, 50Hz / 220V, 60Hz.
Check prior to use
【 Make sure to check them prior to use ! 】
Summary of Contents for ISI-271THN