23
Too low ambient and water temperature (well
below the limitations of respectively 10°C and
5°C - 50°F and 40°F) or frequent interruptions of
the water supply to the freezing cylinder (clog-
ging of thewater hose connecting the float
reservoir to the water inlet at the bottom of the
freezer) may cause the ice to get too hard and
compact loosing fluidity and thereby seizing the
auger.
This situation will put under excessive strain
and load the entire drive system and freezer
bearings.
REFRIGERANT METERING DEVICE:
capillary tube
REFRIGERANT CHARGE (R 134 A)
Air cooled
Water cooled
F 80C
300 gr
300 gr
F 125C
400 gr
300 gr
F 120
440 gr
400 gr
OPERATING PRESSURES
(With 21°C ambient temperature)
Discharge
pressure:
8÷9 bar
8÷5 bar
Suction
pressure:
0.5 bar
0.5 bar
REFRIGERANT CHARGE (R 404 A)
Air cooled
Water cooled
F 200
660 gr
520 gr
SF 300
750 gr
600 gr
SF 500
880 gr
820 gr
SFN 1000
2400 gr
1200 gr
OPERATING PRESSURES
(With 21°C ambient temperature)
Discharge
pressure:
17÷18 bar
17 bar
Suction
pressure:
2.5 bar
2.5 bar
(2.4 bar for SFN 1000)
NOTA.
Before charging the refrigerant system always check the type of refrigerant and quantity as
specified on the individual ice machine dataplate. The refrigerant charges indicated are relatives
to averages operating conditions.
Summary of Contents for F 125C
Page 17: ...15...
Page 35: ...35 WIRING DIAGRAM F 80C Air cooled 220 240 50 1...
Page 36: ...36 WIRING DIAGRAM F 80C Water cooled 220 240 50 1...
Page 37: ...37 WIRING DIAGRAM F 125C Air water cooled 220 240 50 1...
Page 38: ...38 WIRING DIAGRAM F 120 F 200 Air water cooled 220 240 50 1...
Page 39: ...39 WIRING DIAGRAM SF 300 SF 500 Air water cooled 220 240 50 1...
Page 40: ...40 WIRING DIAGRAM SF 500 Air water cooled 400 50 3...
Page 41: ...41 WIRING DIAGRAM SFN 1000 Air water cooled 400 50 3...
Page 47: ......