F. FINAL CHECK LIST
1 Is the unit in a room where ambient tempera-
tures are within a minimum of 10°C (50°F)
even in winter months?
2 Is there at least a 15 cm (6") clearance
around the unit for proper air circulation?
3 Is the unit level? (IMPORTANT)
4 Have all the electrical and plumbing connec-
tions been made, and is the water supply
shut-off valve open?
5 Has the voltage been tested and checked
against the data plate rating?
6 Has the water supply pressure been
checked to ensure a water pressure of at
least 1 bar (14 psi).
7 Have the bolts holding the compressor down
been checked to ensure that the compressor
is snugly fitted onto the mounting pads?
8 Check all refrigerant lines and conduit lines
to guard against vibrations and possible fai-
lure.
9 Have the bin liner and cabinet been wiped
clean?
10Has the owner/user been given the User
Manual and been instructed on the importan-
ce of periodic maintenance checks?
11Has the Manufacturer’s registration card
been filled in properly? Check for correct
model and serial number against the serial
plate and mail the registration card to the fac-
tory.
12Has the owner been given the name and the
phone number of the authorized Service
Agency serving him?
G. INSTALLATION PRACTICE
WARNING. This icemaker is not designed for outdoor installation and will not function in
ambient temperatures below 10°C (50°F) or above 40°C (100°F).
This icemaker will malfunction with water temperatures below 5°C (40°F) or above 35°C
(90°F).
1. Hand shut-off valve
2. Water filter
3. Water supply line (flexible hose)
4. 3/4" GAS male fitting
5. Power line
6. Main switch
7. Drain fitting
8. Vented drain
9. Vented drain
10. Open trapped vented drain
Summary of Contents for F 125C
Page 17: ...15...
Page 35: ...35 WIRING DIAGRAM F 80C Air cooled 220 240 50 1...
Page 36: ...36 WIRING DIAGRAM F 80C Water cooled 220 240 50 1...
Page 37: ...37 WIRING DIAGRAM F 125C Air water cooled 220 240 50 1...
Page 38: ...38 WIRING DIAGRAM F 120 F 200 Air water cooled 220 240 50 1...
Page 39: ...39 WIRING DIAGRAM SF 300 SF 500 Air water cooled 220 240 50 1...
Page 40: ...40 WIRING DIAGRAM SF 500 Air water cooled 400 50 3...
Page 41: ...41 WIRING DIAGRAM SFN 1000 Air water cooled 400 50 3...
Page 47: ......