14
START UP
After having correctly installed the ice maker
and completed the plumbing and electrical
connections, perform the following “Start-up”
procedure.
A
Open the water supply line shutoff valve and
put the unit under electrical power by moving
the main switch, on the power supply line, to
the ON position.
The first
LED - GREEN
- will glow to signal
that unit is under power.
B
Elapsed the stand by period the unit starts
operating with the activation in sequence of
the following assemblies:
GEAR MOTOR/S
COMPRESSOR
FAN MOTOR/S
(if unit is an air cooled version)
kept under control by the condenser tempera-
ture sensor which has its probe within the con-
denser fins (Fig.2).
C
After 2 or 3 minutes from the compressor
start up, observe that flaker ice begins drop-
ping off the ice spout to fall through the ice
chute into the storage bin.
OPERATING INSTRUCTIONS
NOTA.
Every time the unit is put under power,
after being kept for sometime in shut-off
conditions (electrically disconnected) the
RED LED
will blink for 3 minutes (60' on MF
66 only) after which the unit will start up with
the immediate operation of the gear motor
assembly and, after few seconds, of the
compressor (Fig.1).
NOTA.
The first ice bits that drop into the ice
storage bin are not so hard as the evapora-
ting temperature has not yet reached the cor-
rect operating value. It is necessary to allow
the ice - just made - to cure itself and wait for
about ten minutes for the evaporating tempe-
rature to reach the correct value so to make
more hard bits of ice.
Summary of Contents for F 125C
Page 17: ...15...
Page 35: ...35 WIRING DIAGRAM F 80C Air cooled 220 240 50 1...
Page 36: ...36 WIRING DIAGRAM F 80C Water cooled 220 240 50 1...
Page 37: ...37 WIRING DIAGRAM F 125C Air water cooled 220 240 50 1...
Page 38: ...38 WIRING DIAGRAM F 120 F 200 Air water cooled 220 240 50 1...
Page 39: ...39 WIRING DIAGRAM SF 300 SF 500 Air water cooled 220 240 50 1...
Page 40: ...40 WIRING DIAGRAM SF 500 Air water cooled 400 50 3...
Page 41: ...41 WIRING DIAGRAM SFN 1000 Air water cooled 400 50 3...
Page 47: ......