Section 6: MAINTENANCE Page
39
OM-ZR-May15
Vibrator Gear Case
Checking Oil Level:
Check oil level in sight glass located on the lower center of the vibrator gear case. Oil level should be in the
middle of the sight glass.
Adding Oil:
On the vibrator gear case top plate, remove the 1" pipe plug to add oil.
Draining Oil:
Remove ¾” pipe plug at either end of the gear case base plate. Tilt the case for complete drainage.
Power Unit Pump Drive Adapter (350G & 350GZ only)
Checking Oil Level:
Check oil level using the dipstick mounted on the pump drive adapter.
Adding Oil:
Add oil by removing the vent fitting from the top of the pump drive adapter.
of the pump drive adapter.
Draining Oil:
Remove the drain plug on the bottom of the pump drive adapter.
Sight Glass
Drain Plug
Fill Plug
Drain Plug
Vent Fitting
Dip Stick Oil Gauge