Section 4: PREPARATION FOR OPERATION Page 18
OM-ZR-May15
Connecting Vibrator Hoses to Power Unit
The vibrator’s interconnecting hoses (in the bundle) terminate with quick disconnect couplers specific to each
function and mating quick disconnect at the power unit. Use care to connect couplers straight and screw
together completely. Should quick disconnects or hoses require replacement, use care not to mix up the
connectors and hose routing.
Eccentric Moment Actuator
Open Clamp
Motor Return
Motor Pressure
Motor Case Drain
Close Clamp
Gear Oil to Vibro
350GZ Quick Disconnect Panel
The vibrator and hydraulic clamp are connected to the power unit by seven hydraulic hoses. The functions are
listed above on the corresponding quick disconnect couplers.
The hoses connect to the power unit with quick-disconnect couplers. Hose couplers are arranged to insure cor-
rect connections at the power unit .
Clean couplers with a lint-free cloth before making connections.
Make sure that the couplers are fully run up and hand tightened prior to using an appropriate chain type
wrench.
Power unit must be shut down during connection of hydraulic hoses.
Improper hose connections can cause ruptured hoses or damaged components and poor
equipment performance.
!WARNING – Safety!
!WARNING – Equipment!
Gear Oil to Cooler