iCanView240/250 User’s Guide
5.7. Alarm Device Setup
Test the alarm output and describe the condition of alarm annunciation.
Sensor related alarm operation, alarm device can operate only when the sensor is active at least over 2 seconds.
Fig. 5-10 Alarm Device Setup
Field/Button
Sub Field
/Button
Description
Test alarm devices. Click on On/Off for testing
Small box with white background indicates the status of the relay by
On/Off.
ON
On the alarm output (close the relay contact)
Alarm Device
Test
OFF
Off the alarm output (Open the relay contact)
Sound Test
Setup the condition of activating alarm device. Select sensor or motion
detection as the condition.
Name
Logical name of the alarm device can be input into the box at the left.
Sensor
Check at the box at the left of to allow alarm generation upon sensor
input.
Motion
Check at the box at the left to allow alarm generation upon Motion
detection
Alarm Device
Active
Condition
Duration
Set the duration of Alarm annunciation.
10 sec, 30 sec, 1 min, 2 min, 5 min, 10 min, 30 min, 1 hour.
Rev.1.0 (Dec.2006)