The LINK™ Family Manual
Version 1.6 ©iButtonLink, LLC 2016
Page 35
Pass-Thru Mode
Command “ | ” (vertical bar)
Command Compatible With:
Link | LinkHub-S | LinkHub-E | LinkOEM |
LinkUSB
This command will cause the LINK
TM
device to enter a pass-thru mode. In this mode, all activity
on the serial port output line is passed through (inverted) to the 1-Wire® bus, and all activity on
the 1-Wire® bus is inverted to the serial port input line.
This mode can be used to bypass LINK
TM
devices and allow the serial port direct access to the 1-
Wire® bus. Because the device is no longer able to interpret serial data in this mode, the only
way to get out of pass-thru mode is a power-on reset of the LINK
TM