The LINK™ Family Manual
Version 1.6 ©iButtonLink, LLC 2016
Page 32
List of Available Commands
Command “ h ” (lowercase H)
Command Compatible With:
Link | LinkHub-S | LinkHub-E (except for
character commands followed by *) | LinkOEM (except for character
commands followed by
∂
) | LinkUSB (except for character commands followed
by §)
This command displays the list of LINK ASCII commands that are available for the LINK
TM
devices. These are in addition to the standard DS2480/DS9097U binary command codes that are
available. Table 6 shows all single-character commands that are available on the LINK
TM
devices.
N
OTE
:
each line is terminated with <CR><LF>
f = First
\ = Expanded Command Set
∂
n = Next
! = Thru *
§
∂
r = Reset
l = Level
( = Extended
∂
: = 115200 *
§
b = Byt(NN+)
^ = 57600 *
j = Byt(N+)
` = 38400 *
p = BytW/P
, = 19200 *
~ = BitW/P
x = BusLo
d = Aux+
$ = Scan
∂
z = Aux-
* = List
∂
& = Aux?
h = Help
t = Search Type
S
IMILAR
C
OMMAND
(
S
):
•
“ \h ” – Help for commands beginning with “ \ ” (backslash)
Table 6: Table showing single character commands