The LINK™ Family Manual
Version 1.6 ©iButtonLink, LLC 2016
Page 23
Byte Mode with Strong Pull-Up
Command “ p ” (lowercase P)
Command Compatible With:
Link | LinkHub-S | LinkHub-E | LinkOEM |
LinkUSB
This command places the LINK
TM
devices into byte mode with strong pull-up. The next two
characters entered will be taken as a hexadecimal byte value that is then issued onto the bus. The
response byte is then displayed in hexadecimal. Subsequent pairs of hexadecimal characters will
also generate bytes, allowing for streaming of bytes without intervening commands.
Hitting ENTER (carriage return) will end byte mode.
For The LinkHub-E,
“ x ” will also end byte mode.
This command differs from the “ b ” command in that power (strong pull-up) is applied to the
bus after the last bit of the first byte is issued.
Subsequent bytes will be performed but will not be followed by strong pull-up.
S
IMILAR
C
OMMANDS
:
•
“ j ” – Bit Mode
•
“ ~ ” - Bit Mode with Strong Pull-Up
•
“ b ” – Byte Mode
•
“ p ” – Byte Mode with Strong Pull-Up
•
“ . ” – Turn Off Dynamic Pull-Up