Diagnostic
error
codes
The
following
table
describes
the
error
codes
that
the
diagnostic
programs
might
generate
and
suggested
actions
to
correct
the
detected
problems.
If
the
diagnostic
programs
generate
error
codes
that
are
not
listed
in
the
table,
make
sure
that
the
latest
levels
of
BIOS,
Remote
Supervisor
Adapter
II
SlimLine,
and
ServeRAID
code
are
installed.
In
the
error
codes,
x
can
be
any
numeral
or
letter.
However,
if
the
three-digit
number
in
the
central
position
of
the
code
is
000,
195,
or
197,
do
not
replace
a
CRU
or
FRU.
These
numbers
appearing
in
the
central
position
of
the
code
have
the
following
meanings:
000
The
server
passed
the
test.
Do
not
replace
a
CRU
or
FRU.
195
The
Esc
key
was
pressed
to
end
the
test.
Do
not
replace
a
CRU
or
FRU.
197
This
is
a
warning
error,
but
it
does
not
indicate
a
hardware
failure;
do
not
replace
a
CRU
or
FRU.
Take
the
action
that
is
indicated
in
the
Action
column
but
do
not
replace
a
CRU
or
a
FRU
.
See
the
description
of
Warning
in
for
more
information.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
001-292-000
Core
system:
failed/CMOS
checksum
failed.
Load
the
BIOS
default
settings
using
the
Configuration/Setup
Utility
program
and
run
the
test
again
(see
001-xxx-000
Failed
core
tests.
(Trained
service
technician
only)
Replace
the
system
board.
001-xxx-001
Failed
core
tests.
(Trained
service
technician
only)
Replace
the
system
board.
005-xxx-000
Failed
video
test.
(Trained
service
technician
only)
Replace
the
system
board.
011-xxx-000
Failed
COM1
serial
port
test.
(Trained
service
technician
only)
Replace
the
system
board.
015-xxx-001
Failed
USB
test.
(Trained
service
technician
only)
Replace
the
system
board.
015-xxx-198
USB
device
connected
during
USB
test.
1.
Remove
all
USB
devices
and
run
the
test
again.
2.
(Trained
service
technician
only)
Replace
the
system
board.
020-xxx-000
Failed
PCI
Interface
test.
(Trained
service
technician
only)
Replace
the
system
board.
035-xxx-cnn
Failed
hard
disk
drive;
c
=
ServeRAID
channel
number,
nn
=
SCSI
ID
of
failing
fixed
disk
drive.
1.
Reseat
the
hard
disk
drive
on
channel
c
,
SCSI
ID
nn
.
2.
Replace
the
hard
disk
drive
on
channel
c
,
SCSI
ID
nn
.
Chapter
2.
Diagnostics
39
Summary of Contents for xSeries 100
Page 1: ...IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 106: ...90 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 110: ...94 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 120: ...104 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 125: ......
Page 126: ...Part Number 31R2070 Printed in USA 1P P N 31R2070...