Error
code
Description
Action
178x
Fixed
disk
error
(where
x
is
the
drive
number).
1.
Reseat
the
hard
disk
drive
x
cable.
2.
Replace
the
hard
disk
drive
cable.
3.
Run
the
hard
disk
drive
diagnostic
tests.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Hard
disk
drive
x
b.
(Trained
service
technician
only)
System
board
1800
Unavailable
PCI
hardware
interrupt.
1.
Run
the
Configuration/Setup
Utility
program
and
adjust
the
adapter
settings.
2.
Remove
each
adapter
one
at
a
time,
restarting
the
server
each
time,
until
the
problem
is
isolated.
1801
A
PCI
adapter
has
requested
memory
resources
that
are
not
available.
1.
Change
the
order
of
the
adapters
in
the
PCI-X
slots.
Make
sure
that
the
boot
device
is
positioned
early
in
the
scan
order
(see
the
User’s
Guide
for
information
about
the
scan
order).
2.
Make
sure
that
the
settings
for
the
adapter
and
all
other
adapters
in
the
Configuration/Setup
Utility
program
are
correct.
If
the
memory
resource
settings
are
not
correct,
change
them.
3.
If
all
memory
resources
are
being
used,
remove
an
adapter
to
make
memory
available
to
the
adapter.
Disabling
the
BIOS
on
the
adapter
should
correct
the
error.
See
the
documentation
that
comes
with
the
adapter.
1805
PCI
option
ROM
checksum
error.
1.
Remove
the
failing
adapter.
2.
Reseat
each
adapter.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Failing
adapter
b.
(Trained
service
technician
only)
System
board
1810
PCI
error
1.
Remove
any
adapters
installed
in
the
PCI
slots.
2.
(Trained
service
technician
only)
Replace
the
system
board.
Chapter
2.
Diagnostics
19
Summary of Contents for xSeries 100
Page 1: ...IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 106: ...90 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 110: ...94 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 120: ...104 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 125: ......
Page 126: ...Part Number 31R2070 Printed in USA 1P P N 31R2070...