Error
code
Description
Action
035-xxx-snn
Failed
hard
disk
drive
with
SCSI
ID
nn
on
RAID
adapter
in
slot
s
.
1.
Reseat
the
disk
with
SCSI
ID
nn
on
adapter
in
slot
s
.
2.
Replace
the
disk
with
SCSI
ID
nn
on
adapter
in
slot
s
.
035-xxx-099
No
adapters
were
found.
If
an
adapter
is
installed:
1.
Reseat
the
adapter.
2.
Make
sure
that
the
adapter
cables
are
secure.
035-xxx-s99
Failed
RAID
test;
s
=
number
of
failing
adapter
slot.
1.
Reseat
the
following
components:
a.
RAID
adapter
in
slot
s
b.
Cable
for
the
RAID
adapter
in
slot
s
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
RAID
adapter
in
slot
s
b.
Cable
for
the
RAID
adapter
in
slot
s
c.
(Trained
service
technician
only)
System
board
075-xxx-000
Failed
power
supply
test.
1.
(Trained
service
technician
only)
Reseat
the
power
supply.
2.
(Trained
service
technician
only)
Replace
the
power
supply.
201-xxx-0nn
Failed
memory
test;
nn
=
slot
number
of
failing
DIMM.
1.
Reseat
the
DIMM
in
slot
nn
.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMM
in
slot
nn
b.
(Trained
service
technician
only)
System
board
201-xxx-n99
Multiple
DIMM
failure;
n
=
bank
number
of
failing
pair.
1.
See
the
error
text
to
identify
the
failing
DIMMs.
2.
Reseat
the
DIMMs
in
bank
nn
.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMMs
in
bank
nn
b.
(Trained
service
technician
only)
System
board
40
IBM
xSeries
100
Type
8486:
Problem
Determination
and
Service
Guide
Summary of Contents for xSeries 100
Page 1: ...IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 106: ...90 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 110: ...94 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 120: ...104 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 125: ......
Page 126: ...Part Number 31R2070 Printed in USA 1P P N 31R2070...