LED signal cable
(from option package)
2
Hot-swap backplane
signal cable (I C cable)
9. If you are instructed to return the rear hard disk drive cage, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to
you.
Installing an optional hot-swap SAS/SATA rear 2.5-inch hard disk drive
cage
To install the optional rear hot-swap SAS/SATA hard disk drive cage, complete the
following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables.
3. Remove the cover (see “Removing the cover” on page 145).
4. Loosen the screw that secure the drive filler cage to the chassis; then, rotate
the drive filler clockwise and remove the drive filler out of the bay from the
server.