Table 2. Power-supply LEDs
Power-supply LEDs
Description
Action
Notes
AC
(green)
DC
(green)
Error
(amber)
On
On
Off
Normal operation
Off
Off
Off
No ac power to
the server or a
problem with the
ac power source
1. Check the ac power to the server.
2. Make sure that the power cord is
connected to a functioning power
source.
3. Turn the server off and then turn the
server back on.
4. If the problem remains, replace the
power supply.
This is a normal
condition when no
ac power is present.
Off
Off
On
No ac power to
the server or a
problem with the
ac power source
and the power
supply had
detected an
internal problem
1. Replace the power supply.
2. Make sure that the power cord is
connected to a functioning power
source.
This happens only
when a second
power supply is
providing power to
the server.
Off
On
Off
Faulty power
supply
Replace the power supply.
Off
On
On
Faulty power
supply
Replace the power supply.
On
Off
Off
Power supply not
fully seated,
faulty system
board, or faulty
power supply
1. Reseat the power supply.
2. Replace the power supply.
3. (Trained service technician only)
Replace the system board.
Note:
Make sure the technician
refreshes the VPD.
Typically indicates
that a power supply
is not fully seated.
On
Off or
Flashing
On
Faulty power
supply
Replace the power supply.
On
On
On
Power supply is
faulty but still
operational
Replace the power supply.
14
IBM System x3630 M3 Type 7377: Problem Determination and Service Guide
Summary of Contents for x3630 M3 7377
Page 1: ...IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Page 2: ......
Page 3: ...IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Page 40: ...22 IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Page 142: ...124 IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Page 250: ...232 IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Page 293: ......
Page 294: ... Part Number 00D3232 Printed in USA 1P P N 00D3232 ...