Figure
39
shows
the
DS4500
Storage
Server
air
flow.
Make
sure
your
installation
site
allows
adequate
ventilation
to
the
DS4500
Storage
Server
during
operation.
Note:
Allow
at
least
60
cm
(2
ft)
of
clearance
in
front
of
and
behind
the
DS4500
Storage
Server
for
proper
ventilation.
Servicing
notes
Consider
the
following
factors
when
you
service
the
storage
server
fan:
v
The
storage
server
fan
and
the
fan
and
communications
module
cooling
system
failing
simultaneously
in
the
storage
server
is
unlikely.
Such
a
failure
will
cause
either
one
or
both
controllers
to
overheat.
Under
these
circumstances,
the
amber
controller
light
on
the
front
panel
might
be
lit.
If
this
occurs,
shut
down
the
DS4500
Storage
Server
immediately
and
let
the
unit
cool
to
room
temperature
and
then
replace
the
storage
server
fan.
v
You
can
hot
swap,
or
replace,
the
storage
server
fan,
as
long
as
you
complete
the
exchange
within
15
minutes.
The
time
limit
applies
to
the
total
time
that
the
fan
is
out
of
the
chassis.
The
time
begins
when
you
remove
the
failed
storage
server
fan
and
ends
when
you
install
the
new
one.
This
does
not
include
the
time
it
takes
to
perform
the
entire
procedure
(for
example,
checking
the
indicator
lights).
v
When
a
storage
server
fan
fails,
the
fault
light
on
the
storage
server
fan
is
lit.
For
more
information
about
indicator
lights,
see
“Storage
server
indicator
lights”
on
page
26.
v
If
you
replace
the
storage
server
fan
and
still
experience
problems,
the
DS4500
Storage
Server
might
have
defective
components
or
connections.
Check
the
storage-management
software
for
indications
of
other
component
failures.
v
The
storage
server
fan
indicator
light
is
also
used
to
indicate
a
fan
and
communications
module
failure.
Be
sure
to
check
the
storage
server
fan
and
fan
and
communications
module
before
you
call
for
service.
Figure
39.
DS4500
Storage
Server
airflow
Chapter
3.
Replacing
the
DS4500
Storage
Server
components
51
Summary of Contents for TotalStorage DS4500
Page 1: ...IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide GC26 7726 00...
Page 2: ......
Page 3: ...IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide GC26 7726 00...
Page 7: ...Glossary 75 75 Index 85 Contents v...
Page 8: ...vi IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 10: ...viii IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 12: ...x IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 18: ...xvi IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 72: ...42 IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 96: ...66 IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 114: ...84 IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 121: ......
Page 122: ...Part Number 25R0401 Printed in USA GC26 7726 00 1P P N 25R0401...