Servicing
notes
Consider
the
following
factors
when
you
service
the
fan
and
communications
module:
v
The
fan
and
communications
module
contains
two
Ethernet
connections
used
for
direct
network-management.
v
You
can
hot
swap
the
fan
and
communications
module
as
long
as
you
complete
the
exchange
within
15
minutes
from
when
you
remove
the
failed
unit
until
you
install
the
new
one.
v
It
is
unlikely
that
the
storage
server
fan
and
the
fan
and
communications
module
cooling
system
will
fail
simultaneously.
Such
a
failure
will
cause
one
or
both
power
supplies
to
overheat.
In
these
circumstances,
the
amber
power
supply
indicator
light
on
the
bezel
is
lit
and
the
overheated
power
supply
automatically
shuts
down
(the
green
power
indicator
light
on
the
power
supply
turns
off).
Once
the
ambient
air
temperature
cools
below
70°
C
(158°
F),
the
power
supply
automatically
turns
on.
Replace
the
failed
fan
and
communications
module.
Then
check
the
power
supply
indicator
lights
(fault
indicator
light
on
the
front
and
power
indicator
light
on
the
back).
If
the
power
supply
fault
indicator
light
remains
on,
replace
the
power
supply.
For
more
information
about
indicator
lights,
see
“Fan
and
communications
module
indicator
light”
on
page
31
and
Figure
28
on
page
32.
v
If
you
replace
the
fan
and
communications
module
and
still
experience
problems,
the
DS4500
Storage
Server
might
have
defective
components
or
connections.
Check
the
storage-management
software
for
indications
of
other
component
failures.
Replacing
a
failed
fan
and
communications
module
When
instructed
by
the
storage-management
or
diagnostic
software,
replace
the
fan
and
communications
module.
Attention:
To
prevent
damage
to
the
DS4500
Storage
Server
circuitry,
do
not
operate
the
DS4500
Storage
Server
without
adequate
ventilation
to
the
power
supplies
and
mini
hubs.
If
it
will
take
longer
than
15
minutes
to
replace
the
fan
and
communications
module,
you
must
shut
down
the
DS4500
Storage
Server
to
prevent
it
from
overheating.
The
time
limit
applies
only
to
the
total
time
that
the
fan
and
communications
module
is
out
of
the
chassis.
The
time
begins
when
you
remove
the
failed
module
and
ends
when
you
install
the
new
one.
This
does
not
include
the
time
it
takes
you
to
perform
this
entire
procedure
(for
example,
checking
the
indicator
lights).
54
IBM
TotalStorage
DS4500
Fibre
Channel
Storage
Server:
User’s
Guide
Summary of Contents for TotalStorage DS4500
Page 1: ...IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide GC26 7726 00...
Page 2: ......
Page 3: ...IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide GC26 7726 00...
Page 7: ...Glossary 75 75 Index 85 Contents v...
Page 8: ...vi IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 10: ...viii IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 12: ...x IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 18: ...xvi IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 72: ...42 IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 96: ...66 IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 114: ...84 IBM TotalStorage DS4500 Fibre Channel Storage Server User s Guide...
Page 121: ......
Page 122: ...Part Number 25R0401 Printed in USA GC26 7726 00 1P P N 25R0401...