Operational State Change SNMP Traps
The Operational State Change message format is as follows:
3494 [Library Sequence Number] UNSOL 13 [Mode] [State] [Degraded] [Safety
Enclosure Interlock Open] [Vision System Non-Operational] [Intervention
Required] [Check1] [Storage Cells Full] [Out of Cleaners] [Dual Write
Disabled] [Smoke Detected] [Manual Mode] *Operational State Change
Library Sequence Number
Unique Library Sequence Number of the 3494 Tape Dataserver that
generated the SNMP trap message.
Mode
It will be one of the following:
v
AUTO
v
PAUSE
v
MANUAL
State
It will be one of the following:
v
ONLINE
v
OFFLINE
Degraded
It will be one of the following:
v
—
v
DEGRAD
Safety Enclosure Interlock Open
It will be one of the following:
v
—
v
SO
Vision System Non-Operational
It will be one of the following:
v
—
v
VN
Intervention Required
It will be one of the following:
v
—
v
IR
Check1
It will be one of the following:
v
—
v
C1
All Storage Cells Full
It will be one of the following:
v
—
v
SF
Out of Cleaners
It will be one of the following:
v
—
v
OC
Chapter 6. Advanced Operating Procedures
223
Summary of Contents for Tape Library Magstar 3494
Page 1: ...Magstar 3494 Tape Library Operator Guide GA32 0280 09 IBM...
Page 2: ......
Page 3: ...Magstar 3494 Tape Library Operator Guide GA32 0280 09 IBM...
Page 20: ...xviii Magstar 3494 Tape Library Operator Guide...
Page 22: ...xx Magstar 3494 Tape Library Operator Guide...
Page 52: ...30 Magstar 3494 Tape Library Operator Guide...
Page 62: ...40 Magstar 3494 Tape Library Operator Guide...
Page 84: ...62 Magstar 3494 Tape Library Operator Guide...
Page 106: ...84 Magstar 3494 Tape Library Operator Guide...
Page 280: ...258 Magstar 3494 Tape Library Operator Guide...
Page 326: ...304 Magstar 3494 Tape Library Operator Guide...
Page 358: ...336 Magstar 3494 Tape Library Operator Guide...
Page 374: ...352 Magstar 3494 Tape Library Operator Guide...
Page 377: ......