Monitoring the iBBU with the MegaRAID Configuration Utilities
6-7
6.1.2.4
Display BBU Design Parameters
Use the command in
to display BBU design parameters for the
selected controller(s).
6.1.2.5
Display Current BBU Properties
Use the command in
to display the current BBU properties for
the selected controller(s).
Description
Displays BBU capacity information. The information displays in the following format:
BBU Capacity Info for Adapter: x
Relative State of Charge: xx%
Absolute State of Charge: xx%
Remaining Capacity: xx mAh
Full Charge Capacity: xx mAh
Run Time to Empty: xxx Min
Average Time to Empty: xxx Min
Average Time to Full: xxx Min
Cycle Count: xx
Max Error: xx%
Table 6.3
Display BBU Capacity Information (Cont.)
Table 6.4
Display BBU Design Parameters
Convention
MegaCli -AdpBbuCmd -GetBbuDesignInfo –aN|-a0,1,2|-aALL
Description
Displays information about the BBU design parameters. The information displays in
the following formats:
BBU Design Info for Adapter: x
Date of Manufacture: mm/dd, yyyy
Design Capacity: xxx mAh
Design Voltage: mV
Serial Number: 0xhhhh
Pack Stat Configuration: 0xhhhh
Manufacture Name: XXXXXX(String)
Device Name: XXXXXX(String)
Device Chemistry: XXXXXX(String)
Table 6.5
Display Current BBU Properties
Convention
MegaCli -AdpBbuCmd -GetBbuProperties –aN|-a0,1,2|-aALL
Summary of Contents for Redbooks ServeRAID-MR10i
Page 1: ...ServeRAID MR10i USER S GUIDE F e b r u a r y 2 0 0 9 IBM P N 46M1377...
Page 12: ...xii Contents...
Page 14: ...xiv Contents...
Page 16: ...xvi Contents...
Page 58: ...5 6 Installing the Intelligent Battery Backup Unit...
Page 78: ...A 4 Notices...
Page 84: ...B 6 Glossary of Terms and Abbreviations...
Page 85: ......
Page 86: ...4 6 M1 3 7 7...