6-6
Using the Intelligent Battery Backup Unit
6.1.2.3
Display BBU Capacity
Use the command in
to display the BBU capacity for the
selected controller(s).
Description
Displays complete information about the BBU status, such as the temperature and
voltage. The information displays in the following formats:
BBU Status for Adapter: xx
Battery Type: XXXXXX(string)
Voltage: xx mV
Current: xx mA
Temperature: xx C°
Firmware Status: xx
Battery state: xx
Gas Gauge Status:
Fully Discharged: Yes/No
Fully Charged: Yes/No
Discharging: Yes/No
Initialized: Yes/No
Remaining Time Alarm: Yes/No
Remaining Capacity Alarm: Yes/No
Discharge Terminated: Yes/No
Over Temperature: Yes/No
Charging Terminated: Yes/No
Over Charged: Yes/No
Additional status information displays differently for iBBU™ and BBU.
For iBBU:
Relative State of Charge: xx
Charger System State: xx
Charger System Ctrl: xx
Charging Current: xx mA
Absolute State of Charge: xx%
Max Error: xx%
For BBU:
Relative State of Charge: xx
Charger Status: xx
Remaining Capacity: xx mAh
Full Charge Capacity: mAh
isSOHGood: Yes/No
Table 6.2
Display BBU Status Information
Table 6.3
Display BBU Capacity Information
Convention
MegaCli -AdpBbuCmd -GetBbuCapacityInfo –aN|-a0,1,2|-aALL
Summary of Contents for Redbooks ServeRAID-MR10i
Page 1: ...ServeRAID MR10i USER S GUIDE F e b r u a r y 2 0 0 9 IBM P N 46M1377...
Page 12: ...xii Contents...
Page 14: ...xiv Contents...
Page 16: ...xvi Contents...
Page 58: ...5 6 Installing the Intelligent Battery Backup Unit...
Page 78: ...A 4 Notices...
Page 84: ...B 6 Glossary of Terms and Abbreviations...
Page 85: ......
Page 86: ...4 6 M1 3 7 7...