7-2
Intelligent Battery Backup Unit Specifications
7.2
Battery Life and Data Retention Time
The MegaRAID
®
utilities display a counter showing the number of times
the iBBU has been recharged. When you install a new iBBU, the battery
recharge cycle counter for the iBBU is automatically set to zero. For
instructions on installing the iBBU, see
Section 5.1, “Installing the iBBU
on the ServeRAID-MR10i Controller.”
For optimal performance, replace
the battery pack on the iBBU once a year.
The data retention times shown in
are approximate. They can
vary based on a number of factors, including the following:
•
Capacity of the battery pack and the battery load
•
Ambient temperature
•
Age of the battery and number of discharge cycles it has been through
•
Number of DIMMs installed and number of chips on the DIMMs
•
DRAM size
Memory Technology
DDR2 SDRAM (1.8V)
Battery Charge Time
~3 hours
Socket Type
N/A
Module Support
DDR2
Cache Memory Size Supported
128 MB - 256 MB
Memory Bus Speed
667 MHz
Memory Bus Width
Maximum 72-bit
Error Correcting Capability (ECC)
N/A
Table 7.1
Specifications
iBBU
Table 7.2
Reference Data Retention Times
iBBU
Name
Data Retention Times
iBBU
- 72 hours for 512 Mbytes, using five 64 Mx16 parts DDR2 (low power)
- 72 hours for 256 Mbytes, using five 32 Mx16 parts DDR2 (low power)
- 72 hours for 256 Mbytes, using three 64 Mx16 parts DDR2 (low power)
- 72 hours for 128 Mbytes, using three 32 Mx16 DDR2 (low power)
Summary of Contents for Redbooks ServeRAID-MR10i
Page 1: ...ServeRAID MR10i USER S GUIDE F e b r u a r y 2 0 0 9 IBM P N 46M1377...
Page 12: ...xii Contents...
Page 14: ...xiv Contents...
Page 16: ...xvi Contents...
Page 58: ...5 6 Installing the Intelligent Battery Backup Unit...
Page 78: ...A 4 Notices...
Page 84: ...B 6 Glossary of Terms and Abbreviations...
Page 85: ......
Page 86: ...4 6 M1 3 7 7...