6-8
Using the Intelligent Battery Backup Unit
6.1.2.6
Start BBU Learning Cycle
Use the command in
to start the BBU learning cycle on the
selected controller(s). A learning cycle is a battery calibration operation
performed by the controller periodically (approximately every three
months) to determine the condition of the battery.
6.1.2.7
Place Battery in Low-Power Storage Mode
Use the command in
to place the battery into Low-Power
Storage mode on the selected controller(s). This saves battery power
consumption.
6.1.2.8
Set BBU Properties
Use the command in
to set the BBU properties on the selected
controller(s) after reading from the file.
Description
Displays current properties of the BBU. The information displays in the following
formats:
BBU Properties for Adapter: x
Auto Learn Period: xxx Sec
Next Learn Time: xxxx Sec
Learn Delay Interval: xx Hours
Auto-Learn Mode: Warn via Event/Disabled/Enabled
Table 6.5
Display Current BBU Properties (Cont.)
Table 6.6
Start BBU Learning Cycle
Convention
MegaCli -AdpBbuCmd -BbuLearn -aN|-a0,1,2|-aALL
Description
Starts the learning cycle on the BBU. No parameter is needed for this option.
Table 6.7
Place Battery in Low-Power Storage Mode
Convention
MegaCli -AdpBbuCmd -BbuMfgSleep -aN|-a0,1,2|-aALL
Description
Places the battery in Low-Power Storage mode. The battery automatically exits this
state after 5 seconds.
Table 6.8
Set BBU Properties
Convention
MegaCli -AdpBbuCmd -SetBbuProperties -f<fileName> -aN|-a0,1,2|-aALL
Summary of Contents for Redbooks ServeRAID-MR10i
Page 1: ...ServeRAID MR10i USER S GUIDE F e b r u a r y 2 0 0 9 IBM P N 46M1377...
Page 12: ...xii Contents...
Page 14: ...xiv Contents...
Page 16: ...xvi Contents...
Page 58: ...5 6 Installing the Intelligent Battery Backup Unit...
Page 78: ...A 4 Notices...
Page 84: ...B 6 Glossary of Terms and Abbreviations...
Page 85: ......
Page 86: ...4 6 M1 3 7 7...