Updating
System
Firmware
From
the
Service
Processor
Menus
This
procedure
requires
a
diskette
drive
to
be
installed
in
the
system.
This
procedure
also
requires
a
set
of
firmware
update
diskettes
in
backup
format.
The
service
processor
menus
are
available
while
the
system
is
powered
off.
As
a
privileged
user,
from
the
service
processor
main
menu,
select
Service
Processor
Setup
,
then
select
Reprogram
Flash
EPROM
Menu
.
The
update
process
requests
update
diskettes
as
needed.
Updating
System
Firmware
from
the
AIX
Service
Aids
Attention:
This
method
is
not
recommended
for
partitioned
systems,
but
if
the
device
resources
are
allocated
properly,
the
firmware
update
can
be
done
using
the
AIX
service
aid.
Note:
This
service
aid
is
supported
only
in
online
diagnostics.
If
the
firmware
on
a
partitioned
system
is
being
updated:
v
One
partition
running
AIX
must
have
service
authority.
v
All
other
partitions
except
the
one
with
service
authority
must
be
shut
down.
v
The
partition
with
service
authority
must
own
the
device
from
which
the
firmware
update
image
will
be
read.
v
It
is
recommended
that
the
partition
with
service
authority
have
a
hard
disk.
If
the
required
devices
are
not
in
the
partition
with
service
authority,
the
customer
or
system
administrator
must
reassign
the
appropriate
resources
to
it.
This
requires
rebooting
the
partition
with
service
authority.
To
avoid
the
resource
allocation
issues,
it
is
recommended
that
the
service
processor
menus
be
used
to
update
the
firmware.
If
the
firmware
on
a
full
system
partition
is
being
updated,
no
special
steps
are
required
to
perform
the
firmware
update
using
the
service
aid.
For
information
about
updating
system
firmware,
refer
to
the
instructions
that
are
provided
on
the
web
site
with
the
latest
image.
Note:
Because
the
system
always
reboots
itself
during
this
type
of
firmware
update
process,
the
update
process
can
take
from
20
to
60
minutes.
Updating
System
Firmware
from
a
NIM
Server
Refer
to
“Running
Standalone
Diagnostics
from
a
Network
Installation
Management
(NIM)
Server
with
an
HMC
Attached
to
the
System”
on
page
33.
152
Eserver
pSeries
650
Installation
Guide
Summary of Contents for pSeries 650
Page 1: ...pSeries 650 Installation Guide SA38 0610 03 ERserver...
Page 2: ......
Page 3: ...pSeries 650 Installation Guide SA38 0610 03 ERserver...
Page 8: ...vi Eserver pSeries 650 Installation Guide...
Page 12: ...x Eserver pSeries 650 Installation Guide...
Page 14: ...xii Eserver pSeries 650 Installation Guide...
Page 22: ...6 Eserver pSeries 650 Installation Guide...
Page 138: ...122 Eserver pSeries 650 Installation Guide...
Page 142: ...126 Eserver pSeries 650 Installation Guide...
Page 150: ...134 Eserver pSeries 650 Installation Guide...
Page 152: ...136 Eserver pSeries 650 Installation Guide...
Page 164: ...148 Eserver pSeries 650 Installation Guide...
Page 170: ...154 Eserver pSeries 650 Installation Guide...
Page 182: ...166 Eserver pSeries 650 Installation Guide...
Page 186: ...170 Eserver pSeries 650 Installation Guide...
Page 189: ......
Page 190: ...Part Number 80P3834 Printed in USA November 2003 SA38 0610 03 1P P N 80P3834...