Note:
The order of installation is important. You must install the IBM Netfinity Hot
Plug for Windows NT Server 4.0 package before you install the IBM Netfinity
10/100 Fault Tolerant Adapter driver. If you install the adapter device driver
before the PCI Hot Plug Solution package, the adapter device driver will not
recognize the hot-plug code. This happens because the adapter device driver
only checks the NT registry for the Hot Plug package during installation. If
the PCI Hot Plug Solution package is added after the adapter device driver is
installed, the adapter must be removed and added again in order for it to
detect the PCI Hot-Plug Solution code.
To install the IBM Netfinity PCI Hotplug for Windows NT 4.0 Failover DMI Agent:
1. Download the IBM Netfinity PCI Hotplug for Windows NT 4.0 Failover DMI
Agent file from the Netfinity Support web page and extract the files onto a
diskette.
2. Insert the diskette into the diskette drive.
3. From the Start menu, select the Run option.
4. Type A:\SETUP.EXE in the Open box.
5. Click Ok. The setup wizard opens.
6. Follow the instructions that are given by the setup wizard until the program is
installed.
7. Restart the server.
To install the IBM Netfinity PCI Hotplug for Windows NT 4.0 Solution package:
1. Download the IBM Netfinity PCI Hotplug for Windows NT 4.0 Solution file from
the Netfinity Support web page and extract the files onto a diskette.
2. Log on to Windows NT Server as a user in the Administrator group.
3. Insert the diskette into the diskette drive.
4. From the Start menu, select the Run option.
5. Type A:\SETUP.EXE in the Open box.
6. Click OK. The Setup wizard opens.
7. Follow the instructions given by the setup wizard until the program is installed.
Windows NT Server failover setup:
To install the IBM Netfinity 10/100 Fault Tolerant Adapter device drivers:
1. Add the redundant NIC adapter according to the instructions that are provided
with the adapter.
2. Use the ServerGuide CDs to install the AMD PCNet Ethernet Family adapter
device driver.
3. Do not select the Grouping box at this point; you must first restart the machine.
4. From the Windows NT Server desktop, select Control Panel, then select the
Network
icon, then select the Adapters tab.
5. Highlight one of the adapters that will be in the redundant pair and then click the
Properties...
button.
6. Check the Grouping box. This will show the possible combinations for redundant
pairs.
7. Select the adapter pair you want and then select OK. Note that the integrated
Ethernet controller is located at PCI C.
Two options are available for recovering from a failover condition. The options
are determined by the Enable for DMI / Hot Swap Support checkbox. If the IBM
Summary of Contents for Netfinity 6000R
Page 1: ...IBM IBM Netfinity 6000R User s Reference SC19 K081 10...
Page 2: ......
Page 3: ...IBM IBM Netfinity 6000R User s Reference SC19 K081 10...
Page 5: ...IBM...
Page 6: ......
Page 14: ...xii IBM Netfinity 6000R User s Reference...
Page 24: ...10 IBM Netfinity 6000R User s Reference...
Page 36: ...22 IBM Netfinity 6000R User s Reference...
Page 74: ...60 IBM Netfinity 6000R User s Reference...
Page 130: ...116 IBM Netfinity 6000R User s Reference...
Page 198: ...184 IBM Netfinity 6000R User s Reference...
Page 217: ......