If the system-level diagnostics tests...
Then...
Were completed without any failures
1.
Clear the status logs by entering the
following command:
sldiag device clearstatus
2.
Verify that the log is cleared by entering
the following command:
sldiag device status
The following default response is
displayed:
SLDIAG: No log messages are present.
3.
Exit Maintenance mode by entering the
following command:
halt
4.
Enter the following command at the
firmware prompt to reboot the storage
system:
boot
5.
If your system is in an HA pair , run the
cf giveback
command (Data ONTAP
7-Mode) or the
storage failover
giveback
command (Clustered Data
ONTAP) from the partner node console.
You have completed system-level
diagnostics.
Resulted in some test failures
Determine the cause of the problem.
1.
Exit Maintenance mode by entering the
following command:
halt
2.
Perform a clean shutdown and
disconnect the power supplies.
3.
Verify that you have observed all the
considerations identified for running
system-level diagnostics, that cables are
securely connected, and that hardware
components are properly installed in the
storage system.
4.
Reconnect the power supplies and power
on the storage system.
5.
Rerun the system-level diagnostics tests.
Completing the replacement process
Return the failed part to IBM. Contact IBM Service and Support at 1-800-IBM-SERV
(1-800-426-7378) for more information on the return procedure.
Disposing of batteries
Dispose of batteries according to local regulations regarding battery recycling or
disposal.
Replacing N6200 series system devices
93
Summary of Contents for N6270
Page 12: ...xii IBM System Storage N6200 Series Hardware and Service Guide...
Page 16: ...xvi IBM System Storage N6200 Series Hardware and Service Guide...
Page 18: ...xviii IBM System Storage N6200 Series Hardware and Service Guide...
Page 20: ...xx IBM System Storage N6200 Series Hardware and Service Guide...
Page 46: ...20 IBM System Storage N6200 Series Hardware and Service Guide...
Page 130: ...104 IBM System Storage N6200 Series Hardware and Service Guide...
Page 134: ...108 IBM System Storage N6200 Series Hardware and Service Guide...
Page 146: ...120 IBM System Storage N6200 Series Hardware and Service Guide...
Page 147: ......
Page 148: ...Printed in USA GA32 0838 04...