Procedure
1.
Set the specified onboard ports to operate in initiator mode by entering the
following command:
fcadmin config -t initiator
adapter
where
adapter
is the port number. You can specify more than one port.
Example:
The following example sets onboard ports 0c and 0d to initiator
mode.
fcadmin config -t initiator 0c 0d
2.
Reboot the system by entering the following command:
reboot
3.
Verify that the Fibre Channel ports are online and configured in the correct
state for your configuration by entering the following command:
fcadmin config
Example:
The following output example shows two ports configured as Fibre
Channel targets and two ports configured as initiators.
n6000a> fcadmin config
Local
Adapter Type
State
Status
---------------------------------------------------
0a
target
CONFIGURED
online
0b
target
CONFIGURED
online
0c
initiator
CONFIGURED
online
0d
initiator
CONFIGURED
online
Results
For information on converting the onboard ports to target mode and configuring
your SAN, see the
IBM System Storage N series Data ONTAP Block Access
Management Guide
or
IBM System Storage N series Data ONTAP SAN Administration
Guide
for your version of Data ONTAP. This guide, as well as other Data ONTAP
publications, is available on the IBM N series support website, which is accessed
and navigated as described in “Websites” on page xxii.
Configuring and using the Service Processor
The Service Processor (SP) enables you to remotely access, monitor, and
troubleshoot N6200 series systems.
The following table provides a list of documents for configuring and using the
Service Processor. These documents are available on the IBM N series support
website, which is accessed and navigated as described in “Websites” on page xxii.
Table 13. Service Processor manuals
Manual Title
Information Provided
IBM System Storage N series System-Level
Diagnostics Guide
Lists and describes the diagnostic tests for
the Service Processor.
Data ONTAP System Administration Guide
for
your version of Data ONTAP
Describes Service Processor cabling,
configuration and use.
IBM System Storage N series Platform
Monitoring Guide
Lists Service Processor error messages and
gives corrective actions for the error.
22
IBM System Storage: N6200 Series Hardware and Service Guide
Summary of Contents for N6270
Page 12: ...xii IBM System Storage N6200 Series Hardware and Service Guide...
Page 16: ...xvi IBM System Storage N6200 Series Hardware and Service Guide...
Page 18: ...xviii IBM System Storage N6200 Series Hardware and Service Guide...
Page 20: ...xx IBM System Storage N6200 Series Hardware and Service Guide...
Page 46: ...20 IBM System Storage N6200 Series Hardware and Service Guide...
Page 130: ...104 IBM System Storage N6200 Series Hardware and Service Guide...
Page 134: ...108 IBM System Storage N6200 Series Hardware and Service Guide...
Page 146: ...120 IBM System Storage N6200 Series Hardware and Service Guide...
Page 147: ......
Page 148: ...Printed in USA GA32 0838 04...