Replace the fascia
4.
To reinstall the front or PSU fascia, or replace them with parts from FRU stock,
follow the procedure in “Installing or replacing the fascia: 2145-92F” on page
89.
Removing and installing a SAS cable: 2145-92F
Use the following procedures to attach SAS cables to the 2145-92F enclosure during
the initial installation process. You can also remove a faulty SAS cable and replace
it with a new one received from FRU stock.
About this task
Be careful when you are replacing the hardware components that are located in the
back of the system. Do not inadvertently disturb or remove any cables that you are
not instructed to remove.
If you replace more than one cable, record which two ports, canisters, and
enclosures each cable connects, so you can match the connections with the
replacement cables. The system cannot operate if the SAS cabling to the expansion
enclosure is incorrect. See the Installing container of the IBM Knowledge Center for
information about the correct SAS cabling for expansion enclosures.
When the 2145-92F expansion enclosure is installed in the rack, the expansion
canisters are upside down. The input cable connects to the right port (port 1) on
the expansion canister. The output cable connects to the left port (port 2) on the
canister.
svc01032
Figure 94. Fascia removed from the PSUs
Chapter 4. Installing an optional 5U SAS expansion enclosure
97
Summary of Contents for MTM 2145-12F
Page 8: ...viii SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 26: ...xxvi SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 72: ...38 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 192: ...158 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 194: ...160 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 196: ...162 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 200: ...166 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 208: ...174 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 212: ...178 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 213: ......
Page 214: ...IBM Printed in USA GI13 4547 02...