Table 17. Display panel LEDs (continued)
Function
Color
Status
Description
Enclosure fault
Amber
On
The expansion
enclosure is coming
up or a fault is
detected against a
component within
the enclosure.
Off
No faults are
detected.
The 2145-92F expansion enclosure contains two PSUs (
▌4▐
145) that are accessible from the front of the enclosure. Each PSU has its own a set
of LEDs, as shown in Figure 138.
▌1▐
Input power
▌2▐
DC power
▌3▐
Fault indicator
Table 18 explains the function and status that is indicated by each of the LEDs. The
power cords for each PSU are accessible from the rear of the expansion enclosure
(
▌1▐
), as shown in Figure 141 on page 149.
Table 18. Power supply unit LEDs
Function
Color
Status
Description
▌1▐
Input power
Green
On
The input voltage is within
specification.
Off
No power input detected.
▌2▐
DC power
Green
On
DC power outputs are
within specification.
Off
DC power is not available.
▌3▐
Fault
Amber
On
A fault is detected in the
PSU.
Off
No faults are detected.
LEDs inside of the expansion enclosure
Each of the drives and secondary expansion modules within the 2145-92F
expansion enclosure has two LED indicators. To view the drives and secondary
expansion modules, you must remove the cover of the enclosure, as described in
“Removing the top cover: 2145-92F” on page 56.
1
2
3
svc00996
Figure 138. LEDs on the front of a power supply unit
146
SAN Volume Controller: Model 2145-SV1 Hardware Installation Guide
Summary of Contents for MTM 2145-12F
Page 8: ...viii SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 26: ...xxvi SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 72: ...38 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 192: ...158 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 194: ...160 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 196: ...162 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 200: ...166 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 208: ...174 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 212: ...178 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 213: ......
Page 214: ...IBM Printed in USA GI13 4547 02...