1-16
TS3400 Tape Library Maintenance Information
0220
A timeout error occurred
when ejecting cartridge
from Drive #1.
CHK 0220
1.
Confirm the drive connection.
2.
Confirm the media is compatible.
3.
Cycle the power and try again.
4.
Replace the drive canister (page 9-11).
5.
Replace the Drive Docking Card (page 9-19).
6.
Replace the Library Control Blade (page 9-8).
7.
Replace the Back Board assembly (page 9-37).
8.
Replace the TS3400 Tape Library chassis (page 9-44).
0221
The Loop ID setting for
Drive #1 failed.
CHK 0221
1.
Confirm the drive connection.
2.
Verify the drive port configuration (Web User Interface:
Configure Library
→
Physical
).
3.
Cycle the power and try again.
4.
Replace the drive canister (page 9-11).
5.
Replace the Drive Docking Card (page 9-19).
6.
Replace the Library Control Blade (page 9-8).
7.
Replace the Back Board assembly (page 9-37).
8.
Replace the TS3400 Tape Library chassis (page 9-44).
0222
Drive #1 is in Prevent
Medium Removal state,
disabling cartridge
removal.
CHK 0222
1.
Release the Drive #1 Prevent Medium Removal state from
the host.
2.
Cycle the power and try again.
3.
Replace the drive canister (page 9-11).
4.
Replace the Drive Docking Card (page 9-19).
5.
Replace the Library Control Blade (page 9-8).
6.
Replace the Back Board assembly (page 9-37).
7.
Replace the TS3400 Tape Library chassis (page 9-44).
0300
Invalid data was sent to
Drive #2.
NAK was detected.
CHK 0300
1.
Confirm the drive connection.
2.
Cycle the power and try again.
3.
Replace the Library Control Blade (page 9-8).
4.
Replace the drive canister (page 9-11).
5.
Replace the Drive Docking Card (page 9-19).
6.
Replace the Back Board assembly (page 9-37).
7.
Replace the TS3400 Tape Library chassis (page 9-44).
0301
A timeout error occurred
while waiting for response
from Drive #2.
CHK 0301
0303
Drive #2 is disconnected.
CHK 0303
0305
Drive #2 is busy.
CHK 0305
0306
Drive #2 failed to execute
a command because it is
not mounted.
CHK 0306
0320
A timeout error occurred
when ejecting cartridge
from Drive #2.
CHK 0320
1.
Confirm the drive connection.
2.
Confirm the media is compatible.
3.
Cycle the power and try again.
4.
Replace the drive canister (page 9-11).
5.
Replace the Drive Docking Card (page 9-19).
6.
Replace the Library Control Blade (page 9-8).
7.
Replace the Back Board assembly (page 9-37).
8.
Replace the TS3400 Tape Library chassis (page 9-44).
Table 1-2. Drive error codes (continued)
Code (H)
Description
Panel
indication
Action Required
Summary of Contents for L5U
Page 1: ...IBM System Storage TS3400 Tape Library Maintenance Information Machine Type 3577 GA32 0572 03...
Page 2: ......
Page 3: ...IBM System Storage TS3400 Tape Library Maintenance Information Machine Type 3577 GA32 0572 03...
Page 6: ...iv TS3400 Tape Library Maintenance Information...
Page 14: ...xii TS3400 Tape Library Maintenance Information...
Page 52: ...1 36 TS3400 Tape Library Maintenance Information...
Page 84: ...3 14 TS3400 Tape Library Maintenance Information...
Page 92: ...4 8 TS3400 Tape Library Maintenance Information...
Page 106: ...5 14 TS3400 Tape Library Maintenance Information...
Page 109: ...Chapter 6 Installing the Library 6 3 Figure 6 1 Components removed to reduce weight a34z0177...
Page 194: ...8 40 TS3400 Tape Library Maintenance Information...
Page 260: ...11 8 TS3400 Tape Library Maintenance Information...
Page 266: ...12 6 TS3400 Tape Library Maintenance Information...
Page 274: ...B 2 TS3400 Tape Library Maintenance Information...
Page 293: ......
Page 294: ...Part Number 45E5263 Printed in USA GA32 0572 03 1P P N 45E5263...