12.2.12 Vendor unique error information (Byte 20 through 23)
This field gives detailed information about the error. It contains a unique code which describes where the
error was detected and which piece of hardware or microcode detected the error depending on current
operation (that is, Bring-up operation, Read/Write operation, or SMART Alert).
12.2.12.1 Power On Reset/Initialization Error (Sense Key 02h)
For failures in the bring-up operation the Vendor Unique Error information bytes 20 and 21 will contain
"POR Step" which indicates where the failure was detected, and the Vendor Unique Error information
bytes 22 and 23 will contain "POR Error" which is the reason for failure.
Initialization by Usage Table
Bit 0
Start Spinning
Bit 1
Not Used
Bit 2
Not Used
Bit 3
RAM ERP Not Ready
Bit 4
Soft Reset Occurred
Bit 5
Format Corrupted - Degraded Mode
Bit 6
Jumper Setting - Disable Auto Spin-Up
Bit 7
Description
Sense Data
Byte 20
Figure 208. Sense Data Byte 20 for POR STEP
Testing Sector Buffer RAM
Bit 0
Initiate Microcode Loading
Bit 1
Starting Spindle Motor
Bit 2
Loading RAM Code
Bit 3
Loading Overlay Code
Bit 4
Loading Read-Only Table
Bit 5
Head Test Processing
Bit 6
RAM Table Validation
Bit 7
Description
Sense Data
Byte 21
Figure 209. Sense Data Byte 21 for POR STEP
Ultrastar 146Z10 hard disk drive specifications
225
Summary of Contents for IC35L018UCDY10
Page 2: ...This page intentionally left blank ...
Page 16: ...Ultrastar 146Z10 hard disk drive specifications xiv ...
Page 20: ...This page intentionally left blank ...
Page 21: ...Part 1 Functional specification Ultrastar 146Z10 hard disk drive specifications 5 ...
Page 22: ...This page intentionally left blank ...
Page 24: ...This page intentionally left blank ...
Page 34: ...This page intentionally left blank ...
Page 36: ...This page intentionally left blank ...
Page 63: ...Part 2 Interface specification Ultrastar 146Z10 hard disk drive specifications 47 ...