Address to Translate contains the address to translate. If the logical block format is specified, the
first four bytes of the field (bytes 6 to 9) contain the LBA and the remainder must be zero. For the
physical format the address must be specified as follows.
Sector Number or Bytes from Index
10-13
Head Number
9
Cylinder Number
6-8
0
1
2
3
4
5
6
7
Bit
Byte
Figure 161. Address to translate
8.34.3 SEND DIAGNOSTIC Page 80
This requests the drive to perform off-line read scan.
(MSB) Off-line Immediate Time
(LSB)
6
7
Reserved = 0
5
SMART Revision = 03h
4
Page Length = 04h
2-3
Reserved = 0
1
Page Code = 80h
0
0
1
2
3
4
5
6
7
Bit
Byte
Figure 162. SEND DIAGNOSTIC Page 80
!
Off-line Immediate Time specifies the delay to start the off-line read scan in seconds. When this
value is zero, the drive immediately starts the off-line read scan.