8.7.8 Log Sense Page E
This page contains the start-stop cycle information.
Accumulated start-stop cycles
36-39
Parameter Length = 04h
35
LP
= 1
LBIN
= 1
TMC = 0
ETC =
0
TSD =
0
DS
= 1
DU
= 0
34
Parameter Code 0004h
32-33
Start-stop cycles for lifetime
28-31
Parameter Length = 04h
27
LP
= 1
LBIN
= 1
TMC = 0
ETC =
0
TSD =
0
DS
= 1
DU
= 0
26
Parameter Code 0003h
24-25
Accounting Date Week (2 ASCII characters)
22-23
Accounting Date Year (4 ASCII characters)
18-21
Parameter Length = 06h
17
LP
= 1
LBIN
= 0
TMC = 0
ETC =
0
TSD =
0
DS
= 1
DU
= 0
16
Parameter Code 0002h
14-15
Week of Manufacture (2 ASCII characters)
12-13
Year of Manufacture (4 ASCII characters)
8-11
Parameter Length = 06h
7
LP
= 1
LBIN
= 0
TMC = 0
ETC =
0
TSD =
0
DS
= 1
DU
= 0
6
Parameter Code = 0001h
4-5
PageLength = 24h
2-3
Reserved
1
Page code = 0Eh
Reserved
0
0
1
2
3
4
5
6
7
Bit
Byte
Figure 74. Log Sense Page E
The date of manufacture cannot be saved using the LOG SELECT command. The accounting date
specified by parameter code 0002h is blank when the drive is manufactured, it can be saved using the
LOG SELECT command. The start-stop cycles for lifetime is a value of 10000 as the specifications for
start-stop cycle of spindle motor by power on or START STOP UNIT command. The accumulated start-
stop cycle is the count of start-stop cycle of spindle motor by power on or START STOP UNIT command.
Ultrastar 146Z10 hard disk drive specifications
75
Summary of Contents for IC35L018UCDY10
Page 2: ...This page intentionally left blank ...
Page 16: ...Ultrastar 146Z10 hard disk drive specifications xiv ...
Page 20: ...This page intentionally left blank ...
Page 21: ...Part 1 Functional specification Ultrastar 146Z10 hard disk drive specifications 5 ...
Page 22: ...This page intentionally left blank ...
Page 24: ...This page intentionally left blank ...
Page 34: ...This page intentionally left blank ...
Page 36: ...This page intentionally left blank ...
Page 63: ...Part 2 Interface specification Ultrastar 146Z10 hard disk drive specifications 47 ...