8.7.10 Log Sense Page 10
This page contains Self-test results.
Last self-test results log parameter
-403h
First self-test results log parameter
4-
Self-test results log parameters
PageLength = 190h
2-3
Reserved
1
Page code = 10h
Reserved
0
0
1
2
3
4
5
6
7
Bit
Byte
The results of the twenty most recent self-tests are stored in this Log page. The following table describes
the self-test results log parameter structure.
Vendor specific
19
Additional Sense Code Qualifier
18
Additional Sense Code
17
Sense Key
Reserved
16
LBA of First Failure
8-15
Timestamp
6-7
Extended Segment Number
5
Self-Test Results
Value
RSVD
Function Code
4
Parameter Length = 10h
3
LP
= 1
LBIN
= 1
TMC = 0
ETC =
0
TSD
= 0
DS
= 0
DU
= 0
2
Parameter code
0-1
0
1
2
3
4
5
6
7
Bit
Byte
Figure 76. Log Sense Page 10
,
Self-Test Results
!
Parameter Code identifies the log parameter for the log page. The parameter Code field for the
results of the most recent test will be 0001h. The parameter for the next most recent will be 0002h.
!
Function Code contains the content of the Function Code field in the SEND DIAGNOSTIC command
that initiated this self-test.
!
Self-Test Results Value is described in the table below.
Ultrastar 146Z10 hard disk drive specifications
77
Summary of Contents for IC35L018UCDY10
Page 2: ...This page intentionally left blank ...
Page 16: ...Ultrastar 146Z10 hard disk drive specifications xiv ...
Page 20: ...This page intentionally left blank ...
Page 21: ...Part 1 Functional specification Ultrastar 146Z10 hard disk drive specifications 5 ...
Page 22: ...This page intentionally left blank ...
Page 24: ...This page intentionally left blank ...
Page 34: ...This page intentionally left blank ...
Page 36: ...This page intentionally left blank ...
Page 63: ...Part 2 Interface specification Ultrastar 146Z10 hard disk drive specifications 47 ...